Articles & Case Studies

Triark Pumps Services DPF Cleaning Process

Posted: Monday 25th September 2017

Diesel Particulate Filters (DPFs), also known as particulate traps remove particulate matter from diesel engine exhausts. DPFs are becoming increasingly common in trucks, buses and cars owing to stringent international emissions regulations. They are constructed from porous ceramic materials and consist of numerous small channels which are blocked at one end. The exhaust gas enters the DPF through the inlet channels at one end. It is forced through the porous walls of the channels and emerges from the outlet channels. As it passes through the channel walls, the particulate matter is trapped. These wall-flow filters can remove 99% of the particulate matter from the exhaust gases.

The Ceramex cleaning technology is based on 20 years' experience, with more than 140,000 DPFs being successfully cleaned during that period. The inspection technologies employed provide vital evidence of the quality of the cleaning and give reassurance that the cleaned DPF will perform as well as a new par

An important aspect of the onsite process is a filter press, where the effluent which has been produced after the DPF has been cleaned, is itself aggressively washed out and cleaned down via a high pressure AODD pump.

Ceramex first called in Triark Pumps to discuss contingency plans when the original AODD pump required a service, and so had been switched out with a spare pump. Unfortunately, the spare pump failed in a manner that was considered premature so Triark's MD David Rozee rushed to the site fully prepared to get his hands dirty.

Upon arrival the spare pump was still in operation but limping badly, causing considerable disruption to the overall DPF cleaning process. In order to minimise the downtime, and any further disruption, it was decided to quickly service the 'old' original OEM supplied unit, and get it swapped back, so that the new spare pump could be repaired at some leisure.

On initial inspection however, it was quickly determined that the originally supplied Neoprene diaphragm material was inappropriate for the task. Drawing on its 30 years' experience in supplying and maintaining AODD Pumps, Triark not only specified the use of Santoprene diaphragms for this particular application, but the onsite staff were left with an heightened appreciation of the airside operation of AODD pumps.

Commenting on the visit, Colin Lewis, Managing Director at Ceramex said, "We are extremely grateful to David for not only responding to our predicament so quickly - he was onsite in a matter of hours - but for his quick and honest diagnosis and repair. My team now have a better understanding of the pumps operational parameters, which should reduce any such downtime in the future."